Depth of discharge explained
Depth of discharge (DoD) is a percentage that says how much of a battery's stored energy you're meant to draw. [fig:dod-range]
Two meanings, so check which one a sheet uses
Depth of discharge has more than one meaning. Sources use it for the share of capacity removed regularly. They also use it for how much has been removed right now from a charged battery. Which one is meant needs spelling out each time.1
For a spec sheet, the useful reading is the first idea: the part of the battery the system is rated to use. Read the footnote to see which meaning the maker intends.
What the percentage does for you
The glossary calls depth of discharge another metric for the amount of stored energy that is available to you.2 So it is related to usable capacity, but a sheet's usable figure can also include other limits, such as the battery's own power use, so read the sheet's footnotes. The page on usable versus total capacity explains the two figures.
The same glossary says a standard depth of discharge is between 80 percent and 95 percent.2 That's the range it gives, not a target for any particular product.
Why a battery isn't emptied completely
The reference says the battery's own management system, or its charger, can hold the charge level back from the extremes.1 The reference also says that for many battery types, avoiding deep discharge is beneficial, or even mandatory for safety.1
For a home battery, the limit is built in. You don't set it yourself unless your product's manual describes a setting. If it does, follow the manual.
Where 80 percent comes from
Battery University notes that manufacturers often use an 80 percent depth-of-discharge formula to rate a battery.3 In its words, that means only 80 percent of the available energy is delivered and 20 percent remains in reserve.3
That's a rating convention from one source. It doesn't mean every battery on the market uses it, so look at the number on the sheet in front of you.
Depth of discharge and battery life
There is a correlation between depth of discharge and cycle life. The reference says this holds for almost all known rechargeable battery technologies.1 So a cycle life figure only makes sense when you know the DoD it was rated at. That's covered on cycle life ratings.
Reading the line on a sheet
- Find the DoD percentage. Note whether it's stated as a recommended value or a maximum.
- Find the total and usable kWh. Don't assume one can be worked out from the other.
- Read the footnotes. The usable figure may include other limits, such as the battery's own power use.
- Compare DoD across sheets only when the usable kWh is measured the same way.
Who changes the settings
Any change to how a battery is set up in a home is work for a licensed electrician or the maker's approved installer. Don't open a battery or alter its limits.
Reference list
- Depth of discharge, Wikipedia
- Speak storage fluently with these key terms, EnergySage
- BU-501 Basics about Discharging, Battery University