Skip to content

Round-trip efficiency: what is lost between charging and using

Last checked November 20, 2026

Round-trip efficiency is the share of the electricity you put in that you get back out. The rest is lost along the way. It's a ratio, and it only means something when you know how it was measured.

Where round-trip efficiency is measuredEnergy goes in to charge the batterySome is lost as heat and conversionEnergy comes back out for useOut divided by in is the percentage
The ratio compares energy out with the energy put in.

The definition

The Pacific Northwest National Laboratory defines it as a ratio. The top is the energy discharged from a starting state of charge. The bottom is the energy received to bring the system back to that same starting state.1 Its wording is written for storage systems that connect to the electric grid.

Put simply, you charge the battery, then you use that energy. You compare the energy you used with the energy it took to charge. The round trip is the whole loop.

One glossary says the amount of electricity needed to charge a battery and the amount available to discharge are not one to one. There are losses in converting electricity into stored energy and then back into usable electricity.2

Where the losses come from

The laboratory lists several kinds of loss: thermal management, electrochemical, and power conversion, among others.1 The sources here don't give a split between the kinds.

The same glossary describes losses as typically low, in the 5 percent range.2 That's a typical-range remark from one source. Read your own sheet for the real figure.

Is it the same as depth of discharge?

No. The glossary draws the line this way. Depth of discharge measures the electricity stored in a usable battery. Round-trip efficiency measures how much electricity it takes to store that energy in the first place.2 See depth of discharge for the other half.

Test conditions to look for

An efficiency figure comes from a test. A different test can give a different number. The definition above depends on the starting state of charge, so a figure with no stated start is incomplete.1

The sources saved for this page don't list standard test conditions for home batteries. So the practical approach is to read the maker's own footnotes and note what they state. Look for:

  1. The state of charge at the start and the end of the test.
  2. The power or rate used to charge and discharge.
  3. The temperature during the test.
  4. Whether the figure covers only the battery, or the battery and its inverter together.
  5. Whether the figure counts the battery's own standby use or cooling.

If a sheet leaves any of these out, ask the maker which ones apply. A sheet that gives a figure with no conditions is harder to compare.

Battery University adds a general caution, in a passage about cycle counts, that lab numbers may not be reachable in the field.3 Lab and home conditions can differ.

How to use the number

Round-trip efficiency tells you how much of the energy you put in comes back. It doesn't tell you how big the battery is, or how fast it can supply a load. Those are on other lines, covered in kW and kWh and usable versus total capacity.

When you compare two sheets, line up the conditions before you compare the percentages. A one point gap can come from a test difference, not a product difference.

This page covers reading a number. It doesn't give money or running-cost estimates, and it doesn't tell you what a battery would save. For electricity rates or incentives, go to your utility or the official source for your country or state.

Reference list

  1. Energy Storage Subsystems and Definitions, Pacific Northwest National Laboratory
  2. Speak storage fluently with these key terms, EnergySage
  3. BU-808 How to Prolong Lithium-based Batteries, Battery University